Universal AC and DC input, single output, 120, 225 and 350W.
Comparable to EOS and Mean Well.
120W AC/DC Open Frame Power Supply
LOF120-20Bxx Series
FEATURES
- Universal 85 - 264VAC or 120 - 370VDC input voltage
- High power density, compact size: 3” × 2” × 1.22”
- Operating ambient temperature range: -40℃ to +85℃
- Active PFC
- High I/O isolation test voltage up to 4000VAC
- Operating altitude up to 5000m
- Extremely low leakage current<1mA
- Stand-by power consumption<3W
- Conformally-coated assembly
- Output short circuit, over-current, over-voltage, over-temperature protection
- Efficiency up to 95%
- Safety Class I (with PE), Class II (no PE) medical applications
- Safety according to IEC/EN/UL62368-1, IEC/EN60335-1, IEC/EN61558-1, GB4943-1, IEC/EN/ES60601-1(2 × MOPP)

Mornsun LOF120 Openframe


Mornsun LOF120 Enclosed - October 2020 Release
225W AC/DC Open Frame Power Supply
LOF225-20Bxx Series
FEATURES
- Input voltage range: 85 - 264VAC/120 - 370VDC
- Compact size: 4” × 2” × 1”
- Operating ambient temperature range: -40℃ to +70℃
- Active PFC
- High I/O isolation test voltage up to 4000VAC
- Operating altitude up to 5000m
- Very low leakage current <1mA
- No-load power consumption <3W
- Conformally-coated assembly
- Output short circuit, over-current, over-voltage, over-temperature protection
- Safety Class I (with PE), Class II (no PE) medical applications
- Safety according to IEC/EN/UL62368, IEC/EN60335, IEC/EN61558, GB4943, IEC/EN/ES60601

Mornsun LOF225 Openframe

Mornsun LOF225 Openframe Underside - High-Density Component Layout


Mornsun LOF225 Enclosed - October 2020 Release
350W AC/DC Open Frame Power Supply
LOF350-20Bxx Series
FEATURES
- Universal 90 - 264VAC or 127 - 373VDC input voltage
- Compact size: 5” × 3” × 1”
- Accepts AC or DC input (dual use of same terminal)
- Operating ambient temperature range: -40℃ to +70℃
- Built-in active PFC function
- High I/O isolation test voltage up to 4000VAC
- Extremely low leakage current <1mA
- Stand-by power consumption <5W
- Conformally-coated assembly
- Output short circuit, over-current, over-voltage protection, over-temperature protection
- Safety Class I (with PE), Class II (no PE) medical applications
- Safety according to IEC/EN/UL62368, IEC/EN60335, IEC/EN61558, GB4943, IEC/EN/ES60601
- Withstand 300VAC surge input for 5s
- Operating altitude up to 5000m

Mornsun LOF350 Openframe


Mornsun LOF350 Enclosed - October 2020 Release
Mornsun Introduction Video